Title: Energy Efficiency in the Data Center
1(No Transcript)
2Greening of IT Session Learning objectives
- Learn why data centers are at a tipping point.
- Define the term Green Data Center.
- Look at how energy is used in an average data
center. - How to adopt best practices to deliver financial
benefits and reduce the squeeze on IT budgets. - Examples of innovative technologies to improve
your operations. - Ways you can consider to help reduce the
environmental impact of your data centers.
3Situation analyst and recent market surveys
findings
- Gartner predicts that by 2008, 50 of all data
centers will lack sufficient power and cooling
capacity to meet the demands of the new high
density equipment - IDC estimates 50 cents is spent on energy for
every dollar of computer hardware. This is
expected to increase by 54 percent to 71 cents
over the next four years.
IBM Study 2007 found 2 in 3 midsize firms are
implementing or planning to implement new IT
capabilities for energy efficiency
Gartner Study in 2006 ranked the greatest
facilities problem for primary data centers
72
68
66
73
70
Excessive heat
IBM 2007
Insufficient power
Insufficient raised floor
Excessive facility cost
Poor location
None of the above
- Planning
- Implementing
0
5
10
15
20
25
30
35
4Data centers are facing new pressures
- Rising energy cost , demand for computing and
data capacity is growing unabated..IT
departments are beginning to get the energy
bills. - IBM / Consultant studies, September
2007 - Datacenters have doubled their energy use in
the past five years, customers have hit the
wall in terms of power in the data center and
crisis in eliminating heat . - Koomey, February
2007 - 81 of Asia/Pacific respondents think the
Greenness of their IT suppliers will become
much more important over the next few years.
IDC Green Survey, November 2007
EXPENSE Changing Cost Dynamics
OPERATIONAL Increasing Computing Demand
SOCIAL/GOVERNANCE Customer and Employee
Expectations
5CFO, CIO/Facilities and CEO collaboration is
needed
Business Drivers Challenges Looking ahead
Rising global energy prices Squeeze on IT budgets Constraints on IT growth Ability to accurate view baseline energy cost Cost savings from more efficient energy use Relax budgetary pressures to allow growth
Highly dense server systems Aging data center technology Systems availability risks More computing performance per kilowatt Flexibility to adopt more efficient technology Extend the life of IT equipment
Employee desire to help environment Emerging green supply chain Expectation for leadership Measurable energy conservationImproved customer image of your companyProactively address energy/climate challenges
CFO Expense
CIO/Facilities Operational
CEOSocial and Governance
6Worldwide server expenditure is predicted to grow
rapidly
- The emphasis on capital budgeting for server
installation is shifting to a new focus on
reducing the operational expenditure - Energy usage in data center doubled in past 5
years, growing 15-20 annually while utility
rates are rising 10 annually - Most clients electing to reinvest projected
savings allowing them to do more computing on
same budget
Source IDC, Worldwide Server Power and Cooling
Expense 2006-2010, Document 203598, Sept. 2006
7IBM Project Big GreenBig Green Innovations for a
healthy planet
IBM Project Big Green
- IBM to reallocate 1 billion a year
- Armonk, May 10, 2007
- To guarantee the research and development funding
for IT energy efficiency technology. - Create an 850 member worldwide IBM Green Team
of energy efficiency specialists. - Plan, build or prepare data centers to be
increasingly energy efficient based on IBM best
practices and innovative technologies in power
and cooling. - Use virtualization as the technology accelerator
to improve data center energy efficiency to
drive utilization up and annual power cost per
square foot down.
8Relevant aspects of a good environmental program
1. Set goals and document integrated results from
across your business
Between 1990 and 2006, IBMs global energy
conservation actions reduced or avoided CO2
emissions equal to 44 of its 1990 emissions.
Further extend the above achievement by reducing
CO2 emissions 12 between 2005 and 2012 based on
conservation, use of renewable energy, and/or
funding RECs
44
2. Transparency of and the verification in
reporting
Charter member 2003
1605(b) voluntary emissions reporting since 1995
Neuwing Energy Ventures
Charter Member 2000
Energy Efficiency Certificates (EEC) 2007
Charter Member 2002
Since inception
3. Partnerships for improving environmental
performance
The Climate Group 2005
WRI Green Power Market Development Group Charter
member 2000
Program Charter Member 1992
USEPA Climate Protection Award 1998 and 2006
FORTUNE 500 Top 20 2004, 2005, 2006
Green Power Purchaser Award 2006
Business Environmental Leadership Council
9What is a Green Data Center?
- Green data centers are efficient and
environmentally responsible in five strategic
business aspects - IBM client are seeing results
- Up to 40 reduction in power and cooling
- 20 possible increase in server/storage
utilization - Some have achieved 80 reduction in floor space
10Diagnose On-site energy efficiency consultation
for your IT systems
Perform a Server and Storage Power/Cooling Trends
and Data Center Best Practice assessment to
determine the potential cost/energy savings
- What IBM can do for you
- Educate you on the Best Practices for Energy
Efficient use in your data center - Provide insight into the future direction of
computing as it relates to Energy - Review the results and discuss roadmaps to green
data center - Requires only a 4-hour interview for IBM
consultant to gather high level data - Your benefit
- Identify simple to implement, low or no cost,
energy saving ideas - Customized Green Blueprint
- Know your potential savings
- Ability to implement more solutions and
technologies
11Diagnose IBM offers energy efficient services
for entire facilities operations
IBM Data Center - Planning, Design, and
Construction Service Full evaluation report that
includes electrical, mechanical and space
requirements, with equipment layout drawings,
cost estimates and a proposed construction
schedule. IBM Data Center Energy Efficiency
Assessment Compare data center energy efficiency
to industry standards and discovers opportunities
to improve efficiency of the entire data center
ecosystem.
12Diagnose IBM has deep skills to enable energy
efficient installations IT within your data
centers
- IT Systems Energy Efficiency Assessment
- Assessment that analyzes existing IT systems to
provide guidance in strategy to achieve required
IT workload and performance with less power,
cooling, and space requirements. - Data Center Health Audit
- Evaluates the overall heath and readiness of IT
infrastructure. Recommends actions to reduce
risks and improve site availability based on 2-3
week review. - Optimize thermal profile of IT systems to
eliminate hot spots - Utilizing MMT, unique cart-based design for
measurement collection to create 3D temperature
map of IT equipment
Mobile Measurement Technology (MMT)
- The breadth and depth of IBM Development at your
service
13Build Blue Gene not only the fastest, but most
energy efficient system too!
Green500 Rank Machine TOP500 Rank Linpack Rmax (GFlops) Peak Power (kWatts) MFlops/W
1 Blue Gene/L (IBM) 1 280,600 1,494 187.79
2 Mare Nostrum (IBM) 5 62,630 1,071 58.23
3 Jaguar-Cray XT3 (Cray) 10 43,480 1,331 32.67
4 Columbia (SGI) 8 51,870 3,400 15.26
5 ASC Purple (IBM) 4 75,760 7,600 9.97
14Build Innovations to build or upgrade to green
data centers
- IBM Optimized Airflow Assessment for Cabling
- Replace cabling systems with high-performance
fiber transport systems - Yields improved cooling and reduced energy usage
across data center - IBM Scalable Modular Data Center
- Provides ready racking, power, cooling, security
and monitoring - 500 1,000 square foot data centers can be
deployed in 8-12 weeks - About 15 percent below the price of a traditional
approach - IBM manages integration and coordination of data
center
15Build Collaboration with broad energy ecosystem
to holistically attack the issue
- Partnering with leading global data center power
and cooling technology providers - Governments and energy utilities are also helping
clients improve their overall energy efficiency
16Build Be Lean and Green through System z
technology
Confidently combine different types of batch,
transaction, web-facing and core database
production applications on a single system.
10 years (CMOS Evolution) G2 z9 EC
H6
G2
G3
G6
z900
z990
G4
G5
z9 EC
- Performance increased by 103x
- Performance/KWatt increased by 14x
- Performance/sq ft increased by 76x
-
17Build POWER6 Designed for enhanced energy
efficiency
- POWER6 Chip Level Functions
- Power Reduction Monitor reduce power to idle
logic within cores - NAP Mode Power off inactive cores, restore power
when needed - Thermal Tuning Sensors monitor reduce power
to overactive circuits - System p570 Hardware Functions
- Enhanced System Design and Implementation
enables up to 2X server performance uplift over
p5-570 - Variable Fan Speed (10,500 5500 RPM) Reduces
power to fans (1/3 of total server power) by up
to 45 based on ambient temperature - Rear Door Heat Exchanger Cools exhaust air from
19 rack, can reduce system air conditioning
requirements by up to 60
Based on various SPEC benchmarks IBM p570
POWER6 result to be submitted on 5/21/07 Based
on IBM internal measurements IBM press
release 05/10/07 ibm.com/press/us/en/pressreleas
e/21517.wss
18Build IBM BladeCenter Open, Easy, Green
- Efficient system design for energy savings based
on IBM Research - Consolidation extended to network/IO devices
removing the need for extra power supplies and
fans - Get best-in-class efficiency for 20 less power
than offerings from other vendors - Only IBM BladeCenter offers 10G Ethernet
connectivity inside the system - Up to 95 more energy efficient than external
switch solutions
19Build Power efficiency in Information Lifecycle
Management
The ILM Process Managing information through
intelligent archive and destruction
ILM . . . move data to the most cost effective
storage for its current use
Information Lifecycle
content
content
content
content
content
content
lifecycle
lifecycle
lifecycle
lifecycle
lifecycle
lifecycle
Create /
Revise
Route
Approve
Publish
Archive /
Capture
Destroy
Information Management
Classify
Compliance
In the future . . . move data to the most power
efficient storage that satisfies usage
requirements
Corporate Policies
Declare
Audit
Business Rules
Security
Tiered Storage
20Comparison of typical server utilization rates
Used
Wasted
UNIX
x86
Mainframe
21Virtualization Creates fast path to green data
centers
- Improves server and storage utilization which
- Reduces the number of devices and associated
environmentals - Allows for targeted thermal solutions for
efficiencies - Allows for more efficient power distribution,
backup, and regulation - Enables dynamic resource management for
- Deployment and Operational Optimizations
- Some examples
- Base Consolidation
- Policy Based Consolidation
- Policy Based Provisioning
22Do not forget Storage virtualization!
- Pool and share I/O resources for
- Improved utilization
- Reduced energy needs
23Manage and measure Active Energy Management at a
system level
- Helps companies meter, control, even cap their
power usage - Who used what?
- How much did IT cost?
- Chargeback?
24Cool Innovations you can use now
- IBM Heat eXchanger
- Patented cooling doors can reduce heat at the
source by up to 60 and thus reducing associated
HVAC cost. - IBM Data Center Stored Cooling Solution
- The Cool Battery, IBM cut energy cost of IBM
Bromont site by 45 percent - IBM Research owned solution not a formal product.
- Marketing provided by IBM GTS SF
- Example of world class innovation
- IBM already has 350 US patents and patent
applications pertaining to Green Innovation. - IBM overall now has 1300 patents and pending
company wide Green Innovation and Project Big
Green.
25PGE partners with IBM to improve efficiency
- Reduced 80 of their energy and facilities
consumption across 40K square feet - Jointly developed Mobile Measurement Technology
for thermal modelling - 10-80 increase in single system utilization
- IBM System p servers
- Up to 60 heat reduction with IBM technologies
- Deployed IBM Heat eXchanger technology to reduce
heat at the source by up to 60
IBM Heat eXchanger
IBM Mobile Measurement Technology
26IBM best practices, services and innovation
portfolio
- Power Configurator To plan your power usage
- Active Energy Managertm For trending and capping
- Data Center Stored Cooling Solution
- Optimized Airflow Assessment for Cabling
- Scalable Modular Data Center
- Data Center Relocation and Consolidation, Data
Center Facilities Design
- Tivoli Monitoring Aligning power use with
workload goals
- Virtualization on IBM Systems and IBM System
Storage Drives utilization up and annual power
cost down
- Tivoli Provisioning Actively moving workloads
and power up/down resources
- Data Center Energy Efficiency Assessment
- Data Center Thermal Analysis and Optimization
Facilities Integration - IBM Optimization and Integration Services
Server Consolidation - IT Systems Energy Efficiency Assessment
- Data Center Health Audit for IT
- Server and Storage Power/Cooling Trends and
Data Center Best Practices
BladeCenter Open, Easy, Green IBM System StoragetmIncreases utilization reduce energy use IBM System ztmLean and green
X-ArchitecturetmDesigned from the ground up for efficiency Power Architecturetm Processor efficiency management
IBM Power Supplies Measurement built in Rear Door Heat ExchangerThermal management innovation IBM Blue Gene1 efficient system in Green 500
27IBM would like to be your energy-efficiency-partne
r!
- IBM has consulting, product, technical leadership
and skills to enable you to remove current
limitations in your data center. - IBM is working with clients, large and small, to
generate business results from Green Data
Centers. - IBM is a recognized market leader for energy
efficiency.
28Gartners list of Top Ten Technologies for 2008
- Why Green IT is 1
- 2006 many technical barriers and limitations
were overcome. - 2007 moved from a niche to widespread adoption.
- 2008 business are planning new and revised
approach to green.